Nordic Commercial ПОТОЛОЧНО-НАПОЛЬНОГО ТИПА серия

EAC CE RoHS inverter-EUR


ОПИСАНИЕ:

  • Компактные габариты;
  • Дренажный насос;
  • Малошумный вентилятор;
  • Долговечный моющийся фильтр;
  • Автоматическое распределение воздуха в режиме Swing;
  • Самодиагностика нарушений работы основных блоков и режимов;
  • Многоуровневая защита системы;
  • Интеллектуальная разморозка;
  • Длина трубопровода до 50 м.
Auto restart R410A Self diagnosis 24hr Timer mode Super-silent Intelligent-defrost-function Multi-speed-fan Sleep Сooling Dehumidification HeatingAuto-swing-louver-icon1 LED-displayTimer1

МОДЕЛЬНЫЙ РЯД:

CH-IF09NK4 / CH-IU09NK4

Model

CH-IF09NK4 / CH-IU09NK4

Capacity

Cold/warm

kW

2.7/2.9

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

Cold/warm

kW

0.84

0.8

Current rate

Cold/

Warm

A

3.9

3.7

Energy performance

Cold/

Warm

EER/COP

3.21

3.61

Air productive capacity

m3/h

600

Sound-pressure level

Indoor unit

dB(А)

31/29/26/24

52

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

1.2

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1220x700x225/

848х320х540

Weight

indoor unit/outdoor unit

kg

38/34

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

9.53/ 3/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Number of interblock strands (for control)

2*0.75 up to 20 m long

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

3(1.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

30

SEER/SCOP

6.1/3.8

CH-IC12NK4 / CH-IU12NK4

Model

CH-IF12NK4 / CH-IU12NK4

Capacity

Cold/warm

kW

3.50/3.80

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

Cold/warm

kW

1.09

1.05

Current rate

Cold/

Warm

A

5

4.9

Energy performance

Cold/

Warm

EER/COP

3.21

3.61

Air productive capacity

m3/h

700

Sound-pressure level

Indoor unit

dB(А)

35/33/30/27

52

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

1.2

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1220x700x225/

848х320х540

Weight

indoor unit/outdoor unit

kg

39/34

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

9.53/ 3/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Number of interblock strands (for control)

2*0.75 up to 20 m long

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

3(1.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

30

SEER/SCOP

6.1/4.0

CH-IF18NK4 / CH-IU18NK4

Model

CH-IF18NK4/ CH-IU18NK4

Capacity

Cold/warm

kW

5.00/5.60

Electric power supply

~ 380-415V/50Hz/3Ph

Rated input

Cold/warm

kW

1.55

1.55

Current rate

Cold/

Warm

A

7.2

7.2

Energy performance

Cold/

Warm

EER/COP

3.23

3.61

Air productive capacity

m3/h

1000

Sound-pressure level

Indoor unit

dB(А)

44/42/38/32

56

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

1.4

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1220x700x225/

955 х396 х700

Weight

indoor unit/outdoor unit

kg

39/47

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

12.70/ 1/2’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Number of interblock strands (for control)

2*0.75 up to 20 m long

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

3(2.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

60

SEER/SCOP

6.1/4.0

CH-IF24NK4/ CH-IU24NK4

Model

CH-IF24NK4/ CH-IU24NK4

Capacity

Cold/warm

kW

7.00/8.00

Electric power supply

~ 380-415V/50Hz/3Ph

Rated input

Cold/warm

kW

2.18

2.21

Current rate

Cold/

Warm

A

10.1

10.2

Energy performance

Cold/

Warm

EER/COP

3.21

3.62

Air productive capacity

m3/h

1200

Sound-pressure level

Indoor unit

dB(А)

49/48/46/40

57

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

2.2

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1220x700x225/

980х427х790

Weight

indoor unit/outdoor unit

kg

40/67

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

Number of interblock strands (for control)

2*1.0 if longer than 20m

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

5(2.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

60

SEER/SCOP

5.6/4.0

CH-IF30NK4/ CH-IU30NK4

Model

CH-IF30NK4/ CH-IU30NK4

Capacity

Cold/warm

kW

8.50/9.20

Electric power supply

~ 380-415V/50Hz/3Ph

Rated input

Cold/warm

kW

2.67

2.57

Current rate

Cold/

Warm

A

12.4

12

Energy performance

Cold/

Warm

EER/COP

3.18

3.58

Air productive capacity

m3/h

1500

Sound-pressure level

Indoor unit

dB(А)

49/46/44/38

58

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

2.4

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1420x700x225/

980х427х790

Weight

indoor unit/outdoor unit

kg

48/71

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

30

Number of interblock strands (for control)

2*1.0 if longer than 20m

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

5(2.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

60

SEER/SCOP

6.1/4.0

CH-IF36NK4/ CH-IU36NM4

Model

CH-IF36NK4/ CH-IU36NM4

Capacity

Cold/warm

kW

10.00/12.00

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/warm

kW

3.12

3.32

Current rate

Cold/

Warm

A

5.4

5.8

Energy performance

Cold/

Warm

EER/COP

3.21

3.61

Air productive capacity

m3/h

1900

Sound-pressure level

Indoor unit

dB(А)

54/53/51/46

63

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

3.5

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1420x700x245/

1007х440х1100

Weight

indoor unit/outdoor unit

kg

48/98

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

30

Number of interblock strands (for control)

2*1.0 — — if longer than 20 m

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

5(1.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

60

SEER/SCOP

6.1/4.0

CH-IF42NK4/ CH-IU42NM4

Model

CH-IF42NK4/ CH-IU42NM4

Capacity

Cold/warm

kW

11.50/13.50

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/warm

kW

3.9

3.74

Current rate

Cold/

Warm

A

6.7

6.5

Energy performance

Cold/

Warm

EER/COP

3.21

3.61

Air productive capacity

m3/h

1900

Sound-pressure level

Indoor unit

dB(А)

55/54/52/47

61

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

3.7

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1420x700x245/

958х412х1349

Weight

indoor unit/outdoor unit

kg

50/108

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Number of interblock strands (for control)

2*1.0 — — if longer than 20 m

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

5(2.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

60

SEER/SCOP

5.6/4.0

CH-IF48NK4/ CH-IU48NM4

Model

CH-IF48NK4/ CH-IU48NM4

Capacity

Cold/warm

kW

14.00/16.00

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/warm

kW

5.2

4.5

Current rate

Cold/

Warm

A

8.6

7.8

Energy performance

Cold/

Warm

EER/COP

2.80

3.56

Air productive capacity

m3/h

2300

Sound-pressure level

Indoor unit

dB(А)

56/52/50/46

59

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

4

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1720x700x225/

958х412х1349

Weight

indoor unit/outdoor unit

kg

59/114

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Number of interblock strands (for control)

2*1.0 — — if longer than 20 m

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

5(2.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

7.5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

60

SEER/SCOP

5.6/4.0

CH-IF60NK4/ CH-IU60NM4

Model

CH-IF60NK4 / CH-IU60NM4

Capacity

Cold/warm

kW

16.00/17.00

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/warm

kW

5.75

4.7

Current rate

Cold/

Warm

A

10.0

10.2

Energy performance

Cold/

Warm

EER/COP

3.78

3.62

Air productive capacity

m3/h

2500

Sound-pressure level

Indoor unit

dB(А)

58/56/52/46

63

Type of refrigerant coolant

R410a

Refrigerant coolant type

kg

5

Dimensions (width/height/depth)

Indoor unitOutdoor unit/

Indoor unit

mm

1700x700x245/

1085/427/1365

Weight

indoor unit/outdoor unit

kg

59/126

Operational temperature range

Cold/Warm

°C

-15/+48/-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

19.05/ 3/4’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Number of interblock strands (for control)

2*1.0 — — if longer than 20 m

Main power supply area

Outdoor unit

Number of the strands (power supply)

3(1.0mm)/

5(2.5mm)

Factory Freon fill (for the number of the running meters)

r.m.

7.5

Freon per one running meter (surplus. per each running meter)

gr/r.m.

60

SEER/SCOP

5.1/4.0


CH-F18NK / CH-U18NK

Mодель

CH-F18NK / CH-U18NK

Производительность

холод/тепло

кВт

5.00/5.70

Источник электропитания

~220-240V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

2.03/2.07

Сила тока

холод/тепло

А

9.30/9.50

Энергоэффективность

холод/тепло

EER/COP

2.46/2.75

Воздухопроизводительность

м3

570/640/700

Уровень звукового давления

вн. блок

дБ(А)

46/50/54

Уровень звукового давления

нар. блок

дБ(А)

56

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн.блок/нар.блок

мм

836х695х238 /

820х540х320

Вес

вн.блок/нар.блок

кг

26/40

Объем хладагента

кг

1.5

Температурный диапазон работы

холод/тепло

°C

+18/+43 / -7/+24

Диаметр жидкостной магистрали

мм/дюйм

6.35 / 1/4’’

Диаметр газовой магистрали

мм/дюйм

12.70/1/2”

Максимальный перепад высоты магистрали

м

15

Максимальная длина магистрали

м

20

Расстояние между болтами крепления нар. блока

мм

540

Количество межблочных жил (на управлении)

2*0.75 — при длине до 20 м

Место подачи осн. питания

наруж.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 мм)/ 3(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

5

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

15

CH-F24NK /CH-U24NK

Mодель

CH-F24NK /CH-U24NK

Производительность

холод/тепло

кВт

7.00/8.00

Источник электропитания

~220-240V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

2.61/2.59

Сила тока

холод/тепло

А

11.80/11.70

Энергоэффективность

холод/тепло

EER/COP

2.68/3.09

Воздухопроизводительность

м3

1000/1080/1170

Уровень звукового давления

вн. блок

дБ(А)

46/48/50

Уровень звукового давления

нар. блок

дБ(А)

59

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн.блок/нар.блок

мм

1300х600х188/

1018х695х412

Вес

вн.блок/нар.блок

кг

33/59

Объем хладагента

кг

2.2

Температурный диапазон работы

холод/тепло

°C

+18/+43 / -7/+24

Диаметр жидкостной магистрали

мм/дюйм

9.53/3/8”

Диаметр газовой магистрали

мм/дюйм

15.88/5/8”

Максимальный перепад высоты магистрали

м

15

Максимальная длина магистрали

м

30

Расстояние между болтами крепления нар. блока

мм

572

Количество межблочных жил (на управлении)

2*0.75 — при длине до 20 м

Место подачи осн. питания

наруж.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 мм)/ 3(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

5

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

60

CH-F36NK / CH-U36NM

Mодель

CH-F36NK / CH-U36NM

Производительность

холод/тепло

кВт

9.80/10.80

Источник электропитания

~380-415V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

3.60/3.30

Сила тока

холод/тепло

А

6.70/6.00

Энергоэффективность

холод/тепло

EER/COP

2.72/3.27

Воздухопроизводительность

м3

1520/1630/1800

Уровень звукового давления

вн. блок

дБ(А)

48/51/54

Уровень звукового давления

нар. блок

дБ(А)

60

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн.блок/нар.блок

мм

1590х695х238/

1018х840х412

Вес

вн.блок/нар.блок

кг

48/90

Объем хладагента

кг

3.2

Температурный диапазон работы

холод/тепло

°C

+18/+43 / -7/+24

Диаметр жидкостной магистрали

мм/дюйм

12.70 / 1/2’’

Диаметр газовой магистрали

мм/дюйм

19.05/3/4”

Максимальный перепад высоты магистрали

м

30

Максимальная длина магистрали

м

50

Расстояние между болтами крепления нар. блока

мм

572

Количество межблочных жил (на управлении)

2*1.0 – при длине более 20 м

Место подачи осн. питания

наруж.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 мм)/ 5(2.5 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

5

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

120

CH-F48NK /CH-U48NM

Mодель

CH-F48NK /CH-U48NM

Производительность

холод/тепло

кВт

13.20/14.50

Источник электропитания

~380-415V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

5.00/4.80

Сила тока

холод/тепло

А

9.20/8.40

Энергоэффективность

холод/тепло

EER/COP

2.64/3.02

Воздухопроизводительность

м3

1800/1900/2100

Уровень звукового давления

вн. блок

дБ(А)

52/55/58

Уровень звукового давления

нар. блок

дБ(А)

63

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн.блок/нар.блок

мм

1590х695х238/

1032х1250х412

Вес

вн.блок/нар.блок

кг

48/112

Объем хладагента

кг

3.8

Температурный диапазон работы

холод/тепло

°C

+18/+43 / -7/+24

Диаметр жидкостной магистрали

мм/дюйм

12.70/1/2”

Диаметр газовой магистрали

мм/дюйм

19.05/3/4”

Максимальный перепад высоты магистрали

м

30

Максимальная длина магистрали

м

Расстояние между болтами крепления нар. блока

мм

572

Количество межблочных жил (на управлении)

2*1.0 – при длине более 20 м

Место подачи осн. питания

наруж.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 мм)/ 5(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

5

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

120

CH-F60NK / CH-U60NM

Mодель

CH-F60NK / CH-U60NM

Производительность

холод/тепло

кВт

15.50/18.50

Источник электропитания

~380-415V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

6.00/5.30

Сила тока

холод/тепло

А

10.90/9.60

Энергоэффективность

холод/тепло

EER/COP

2.58/3.49

Воздухопроизводительность

м3

1900/2100/2300

Уровень звукового давления

вн. блок

дБ(А)

52/55/58

Уровень звукового давления

нар. блок

дБ(А)

64

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн.блок/нар.блок

мм

1700x700x245

Вес

вн.блок/нар.блок

кг

65/123

Объем хладагента

кг

4.5

Температурный диапазон работы

холод/тепло

°C

+18/+43 / -7/+24

Диаметр жидкостной магистрали

мм/дюйм

12.70/1/2”

Диаметр газовой магистрали

мм/дюйм

19.05/3/4”

Максимальный перепад высоты магистрали

м

30

Максимальная длина магистрали

м

Расстояние между болтами крепления нар. блока

мм

572

Количество межблочных жил (на управлении)

2*1.0 – при длине более 20 м

Место подачи осн. питания

наруж.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 мм)/ 5(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

7.5

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

120

Cooper & Hunter Support

-

Support 24H

Please fill out all required fields