МОДЕЛЬНЫЙ РЯД:

CH-IC12NK4 / CH-IU12NK4

Model

CH-IC12NK4 / CH-IU12NK4

Capacity

Cold

kW

3.5

Capacity

Warm

kW

3.8

Electric power supply

~220-240V/50Hz/1Ph

Rated input

Cold/

kW

1.09

Rated input

Warm

1.05

Current rate

Cold/

А

5

Current rate

Warm

4.9

Energy performance

Cold/

EER/ COP

3.21/

Energy performance

Warm

3.61

Air productive capacity

indoor unit

m3/h

700

Sound-pressure level

indoor unit/outdoor unit

dB(A)

46/45/41/36

52

Type of refrigerant coolant

R410A

Refrigerant coolant type

kg

1.2

Dimensions (width/height/depth)

indoor unit

mm

596х596х240

Dimensions (width/height/depth)

indoor unit panel

mm

670х670х50

Dimensions (width/height/depth)

outdoor unit

mm

848х320х540

Weight

indoor unit/outdoor unit

kg

20/34

Operational temperature range

Cold/

Warm

°C

-15/+48

-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

9.53/ 3/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Number of interblock strands (for control)

2*0.75–up to 20 m

Main power supply area

outdoor

Number of the strands (power supply)

3(1.0mm.)/

3(1.5mm.)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freonperonerunningmeter (surplus. per each running meter)

gramm/r.m.

30

SEER/SCOP

5.6/4.0

CH-IC18NK4 / CH-IU18NK4

Model

CH-IC18NK4 / CH-IU18NK4

Capacity

Cold

kW

5.0

Capacity

Warm

kW

5.5

Electric power supply

~220-240V/50Hz/1Ph

Rated input

Cold/

kW

1.6

Rated input

Warm

1.58

Current rate

Cold/

А

7.2

Current rate

Warm

7.6

Energy performance

Cold/

EER/ COP

3.12/

Energy performance

Warm

3.48

Air productive capacity

indoor unit

m3/h

760

Sound-pressure level

indoor unit/outdoor unit

dB(A)

47/46/44/37

56

Type of refrigerant coolant

R410A

Refrigerant coolant type

kg

1.4

Dimensions (width/height/depth)

indoor unit

mm

596х596х240

Dimensions (width/height/depth)

indoor unit panel

mm

670х670х50

Dimensions (width/height/depth)

outdoor unit

mm

955х396х700

Weight

indoor unit/outdoor unit

kg

20/47

Operational temperature range

Cold/

Warm

°C

-15/+48

-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

12.70/ 1/2’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Number of interblock strands (for control)

2*0.75–up to 20 m

Main power supply area

outdoor

Number of the strands (power supply)

3(1.0mm.)/

3(2.5mm.)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freonperonerunningmeter (surplus. per each running meter)

gramm/r.m.

30

SEER/SCOP

5.6/3.8

CH-IC24NK4 / CH-IU24NK4

Model

CH-IC24NK4 / CH-IU24NK4

Capacity

Cold

kW

7.0

Capacity

Warm

kW

8.0

Electric power supply

~220-240V/50Hz/1Ph

Rated input

Cold/

kW

2.18

Rated input

Warm

2.21

Current rate

Cold/

А

10.1

Current rate

Warm

10.2

Energy performance

Cold/

EER/ COP

3.21/

Energy performance

Warm

3.61

Air productive capacity

indoor unit

m3/h

1300

Sound-pressure level

indoor unit/outdoor unit

dB(A)

47/46/42/38

57

Type of refrigerant coolant

Refrigerant coolant type

kg

2.2

Dimensions (width/height/depth)

indoor unit

mm

840х840х240

Dimensions (width/height/depth)

indoor unit panel

mm

950х950х60

Dimensions (width/height/depth)

outdoor unit

mm

980х427х790

Weight

indoor unit/outdoor unit

kg

26/67

Operational temperature range

Cold/

Warm

°C

-15/+48

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

Number of interblock strands (for control)

2*0.75–up to 20 m

Main power supply area

outdoor

Number of the strands (power supply)

3(1.0mm.)/

3(2.5mm.)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freonperonerunningmeter (surplus. per each running meter)

gramm/r.m.

60

SEER/SCOP

6.1/4.0

CH-IC36NK4 / CH-IU36NK4

Model

CH-IC36NK4 / CH-IU36NM4

Capacity

Cold

kW

10.0

Capacity

Warm

kW

12.0

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/

kW

3.12

Rated input

Warm

3.32

Current rate

Cold/

А

5.4

Current rate

Warm

5.8

Energy performance

Cold/

EER/ COP

3.2/

Energy performance

Warm

3.6

Air productive capacity

indoor unit

m3/h

1860

Sound-pressure level

indoor unit/outdoor unit

dB(A)

51/49/46/43

63

Type of refrigerant coolant

Refrigerant coolant type

kg

3.5

Dimensions (width/height/depth)

indoor unit

mm

840х840х320

Dimensions (width/height/depth)

indoor unit panel

mm

950х950х60

Dimensions (width/height/depth)

outdoor unit

mm

1107х440х1100

Weight

indoor unit/outdoor unit

kg

31/98

Operational temperature range

Cold/

Warm

°C

-15/+48

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

Number of interblock strands (for control)

2*1.0 –if longer than 20 m

Main power supply area

outdoor

Number of the strands (power supply)

3(1.0 mm)/

5(1.5 mm)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freonperonerunningmeter (surplus. per each running meter)

gramm/r.m.

60

SEER/SCOP

6.1/4.0

CH-IC42NK4 / CH-IU42NK4

Model

CH-IC42NK4 / CH-IU42NM4

Capacity

Cold

kW

11.0

Capacity

Warm

kW

12.5

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/

kW

3.9

Rated input

Warm

3.8

Current rate

Cold/

А

6.7

Current rate

Warm

6.6

Energy performance

Cold/

EER/ COP

2.82/

Energy performance

Warm

3.29

Air productive capacity

indoor unit

m3/h

1860

Sound-pressure level

indoor unit/outdoor unit

dB(A)

51/49/46/43

61

Type of refrigerant coolant

Refrigerant coolant type

kg

3.7

Dimensions (width/height/depth)

indoor unit

mm

840х840х320

Dimensions (width/height/depth)

indoor unit panel

mm

950х950х60

Dimensions (width/height/depth)

outdoor unit

mm

958х412х1349

Weight

indoor unit/outdoor unit

kg

31/108

Operational temperature range

Cold/

Warm

°C

-15/+48

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Number of interblock strands (for control)

2*1.0 –if longer than 20 m

Main power supply area

outdoor

Number of the strands (power supply)

3(1.0mm.)/

3(2.5mm.)

Factory Freon fill (for the number of the running meters)

r.m.

5

Freonperonerunningmeter (surplus. per each running meter)

gramm/r.m.

60

SEER/SCOP

6.1/4.0

CH-IC48NK4 / CH-IU48NK4

Model

CH-IC48NK4 / CH-IU48NM4

Capacity

Cold

kW

14.0

Capacity

Warm

kW

16.0

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/

kW

5.15

Rated input

Warm

4.5

Current rate

Cold/

А

8.9

Current rate

Warm

7.8

Energy performance

Cold/

EER/ COP

2.72/

Energy performance

Warm

3.56

Air productive capacity

indoor unit

m3/h

2300

Sound-pressure level

indoor unit/outdoor unit

dB(A)

53/52/47/41

59

Type of refrigerant coolant

Refrigerant coolant type

kg

4

Dimensions (width/height/depth)

indoor unit

mm

910х910х290

Dimensions (width/height/depth)

indoor unit panel

mm

1040х1040х65

Dimensions (width/height/depth)

outdoor unit

mm

958х412х1349

Weight

indoor unit/outdoor unit

kg

43/114

Operational temperature range

Cold/

Warm

°C

-15/+48

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Number of interblock strands (for control)

2*1.0 –if longer than 20 m

Main power supply area

outdoor

Number of the strands (power supply)

3(1.0 mm)/

5(2.5 mm)

Factory Freon fill (for the number of the running meters)

r.m.

7.5

Freonperonerunningmeter (surplus. per each running meter)

gramm/r.m.

60

SEER/SCOP

5.6/3.8

CH-IC60NK4 / CH-IU60NK4

Model

CH-IC60NK4 / CH-IU60NM4

Capacity

Cold

kW

16.0

Capacity

Warm

kW

17.0

Electric power supply

~380-415V/50Hz/3Ph

Rated input

Cold/

kW

5.7

Rated input

Warm

4.2

Current rate

Cold/

А

9.8

Current rate

Warm

8.2

Energy performance

Cold/

EER/ COP

2.81/

Energy performance

Warm

3.6

Air productive capacity

indoor unit

m3/h

2400

Sound-pressure level

indoor unit/outdoor unit

dB(A)

55/53/47/46

63

Type of refrigerant coolant

Refrigerant coolant type

kg

5

Dimensions (width/height/depth)

indoor unit

mm

910х910х290

Dimensions (width/height/depth)

indoor unit panel

mm

1040х1040х65

Dimensions (width/height/depth)

outdoor unit

mm

1085х427х1365

Weight

indoor unit/outdoor unit

kg

43/126

Operational temperature range

Cold/

Warm

°C

-15/+48

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

19.05/ 3/4’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Number of interblock strands (for control)

2*1.0 –if longer than 20 m

Main power supply area

outdoor

Number of the strands (power supply)

3(1.0 mm)/

5(2.5 mm)

Factory Freon fill (for the number of the running meters)

r.m.

7.5

Freonperonerunningmeter (surplus. per each running meter)

gramm/r.m.

60

SEER/SCOP

6.1/4.0


CH-C18NK2 / CH-U18NK2

Moдель

CH-C18NK2 / CH-U18NK2

Производительность

холод/тепло

кВт

5.00/5.40

Источник электропитания

~220-240V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

2.00/1.90

Сила тока

холод/тепло

А

9.20/8.60

Энергоэффективность

холод/тепло

EER/COP

2.50/2.84

Воздухопроизводительность

м3

720/640/

580/520

Диапазон давлений

вн. блок

дБ(А)

50/49/47/46

Уровень звукового давления

нар. блок

дБ(А)

56

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн. блок/

панель вн. блок/

нар.блок

мм

665/240/595

670/50/670

955/700/395

Вес

вн.блок/нар.блок

кг

20/53

Объем хладагента

кг

1.3

Температурный диапазон работы

холод/тепло

°C

-15/+43 / -10/+24

Диаметр жидкостной магистрали

мм/дюйм

6.35/1/4”

Диаметр газовой магистрали

мм/дюйм

12.70/1/2”

Максимальный перепад высоты магистрали

м

15

Максимальная длина магистрали

м

15

Расстояние между болтами крепления нар. блока

мм

560

Количество межблочных жил (на управлении)

2*0.75–при длине до 20 м

Место подачи осн. питания

наружн.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 мм)/ 3(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

7

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

15

CH-C24NK2 /CH-U24NK2

Moдель

CH-C24NK2 /CH-U24NK2

Производительность

холод/тепло

кВт

7.00/7.60

Источник электропитания

~220-240V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

2.50/2.40

Сила тока

холод/тепло

А

11.40/10.40

Энергоэффективность

холод/тепло

EER/COP

2.80/3.16

Воздухопроизводительность

м3

1470/1300/

1220/1170

Диапазон давлений

вн. блок

дБ(А)

49/48/47/46

Уровень звукового давления

нар. блок

дБ(А)

59

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн. блок/

панель вн. блок/

нар.блок

мм

840/240/840

950/60/950

955/700/395

Вес

вн.блок/нар.блок

кг

27/61

Объем хладагента

кг

1.5

Температурный диапазон работы

холод/тепло

°C

-15/+43 / -10/+24

Диаметр жидкостной магистрали

мм/дюйм

9.53/3/8”

Диаметр газовой магистрали

мм/дюйм

15.88/5/8”

Максимальный перепад высоты магистрали

м

15

Максимальная длина магистрали

м

15

Расстояние между болтами крепления нар. блока

мм

560

Количество межблочных жил (на управлении)

2*0.75–при длине до 20 м

Место подачи осн. питания

наружн.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 mm)/ 3(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

7

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

60

CH-C36NK2 /CH-U36NM2

CH-C36NK2 /CH-U36NM2

Производительность

холод/тепло

кВт

10.00/11.00

Источник электропитания

~380-415V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

3.50/3.30

Сила тока

холод/тепло

А

7.50/7.20

Энергоэффективность

холод/тепло

EER/COP

2.85/3.48

Воздухопроизводительность

м3

1650/1610/

1500/1300

Диапазон давлений

вн. блок

дБ(А)

52/47/46/43

Уровень звукового давления

нар. блок

дБ(А)

60

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн. блок/

панель вн. блок/

нар.блок

мм

850/325/850

950/60/950

980/790/425

Вес

вн.блок/нар.блок

кг

32/69

Объем хладагента

кг

2.2

Температурный диапазон работы

холод/тепло

°C

-15/+43 / -10/+24

Диаметр жидкостной магистрали

мм/дюйм

9.53/3/8”

Диаметр газовой магистрали

мм/дюйм

19.05/3/4”

Максимальный перепад высоты магистрали

м

30

Максимальная длина магистрали

м

30

Расстояние между болтами крепления нар. блока

мм

610

Количество межблочных жил (на управлении)

2*1.0 –придлине более 20 м

Место подачи осн. питания

наружн.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 mm)/ 5(2.5 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

7

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

120

CH-C48NK2 /CH-U48NM2

CH-C48NK2 /CH-U48NM2

Производительность

холод/тепло

кВт

13.20/14.50

Источник электропитания

~380-415V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

4.80/4.90

Сила тока

холод/тепло

А

9.40/9.60

Энергоэффективность

холод/тепло

EER/COP

2.91/3.02

Воздухопроизводительность

м3

1650/1610/

1500/1300

Диапазон давлений

вн. блок

дБ(А)

52/47/46/43

Уровень звукового давления

нар. блок

дБ(А)

60

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн. блок/

панель вн. блок/

нар.блок

мм

850/325/850

950/60/950

1120/1100/440

Вес

вн.блок/нар.блок

кг

34/103

Объем хладагента

кг

3.7

Температурный диапазон работы

холод/тепло

°C

-15/+43 / -10/+24

Диаметр жидкостной магистрали

мм/дюйм

12.70/1/2”

Диаметр газовой магистрали

мм/дюйм

19.05/3/4”

Максимальный перепад высоты магистрали

м

30

Максимальная длина магистрали

м

30

Расстояние между болтами крепления нар. блока

мм

631

Количество межблочных жил (на управлении)

2*1.0 –придлине более 20 м

Место подачи осн. питания

наружн.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 mm)/ 5(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

7

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

120

CH-C60NK 2/ CH-U60NM2

Moдель

CH-C60NK 2/ CH-U60NM2

Производительность

холод/тепло

кВт

15.50/18.00

Источник электропитания

~380-415V/50Hz/1Ph

Номинальная потребляемая мощность

холод/тепло

кВт

5.30/5.20

Сила тока

холод/тепло

А

10.50/10.30

Энергоэффективность

холод/тепло

EER/COP

2.83/3.23

Воздухопроизводительность

м3

1800/1750/

1650/1450

Диапазон давлений

вн. блок

дБ(А)

53/51/49/47

Уровень звукового давления

нар. блок

дБ(А)

61

Tип хладагента

R410a

Габаритные размеры (Ш/В/Г)

вн. блок/

панель вн. блок/

нар.блок

мм

840/290/840

950/60/950

980/1350/410

Вес

вн.блок/нар.блок

кг

37/118

Объем хладагента

кг

4.1

Температурный диапазон работы

холод/тепло

°C

-15/+43 / -10/+24

Диаметр жидкостной магистрали

мм/дюйм

12.70/1/2”

Диаметр газовой магистрали

мм/дюйм

19.05/3/4”

Максимальный перепад высоты магистрали

м

30

Максимальная длина магистрали

м

30

Расстояние между болтами крепления нар. блока

мм

572

Количество межблочных жил (на управлении)

2*1.0 –придлине более 20 м

Место подачи осн. питания

наружн.

Количество жил (подача питания внутр./нар.)

вн.блок/нар.блок

3(1.0 mm)/ 5(4.0 мм)

Заводская заправка фреоном (на кол-во метров погонных)

м.п.

9.5

Кол-во заправки фреоном на м.п. (превышение, на каждый метр погонный)

грамм/м.п.

120

Cooper & Hunter Support

-

Support 24H

Please fill out all required fields