Õhksoojuspump NORDIC seeria

SPETSIAALSELT PÕHJAMAADESSE LOODUD

Professionalne seeria on spetsiaalselt välja töötatud kõrgtasemel paigalduseks

 

EAC CE RoHS inverter-EUR


KIRJELDUS:

  • Kodukasutuse soojuspump. Seadistatud just töötamiseks Põhjala riikides
  • Kompressori ja alusplaadi soojendamine, ventilaatori pöörlemiskiiruse juhtseade välisseadmes
  • Temperatuurivahemik: jahutamisel + 18 °C kuni + 48 °C, kütmisel -20 °C kuni + 24 °C
Active-carbon-filter Auto restart Auto swing louver Generation IV G-matrik IONIZER R410A Self diagnosis Self diagnosis error protection Warranty 24hr Timer mode Intelligent-defrost-function LED-displaySleep Сooling Dehumidification Heating

MUDELID:

CH-S09FTXN

Model

CH-S09FTXN

Capacity

Cold/Warm

kW

2.70(0.44-3.26)/3.60(0.44-4.20)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

Cold/Warm

kW

0.68 (0.20-1.35)/0.87(0.20-1.45)

Energy performance

EER (Cold)/C.O.P.(Warm)

kW/kW

3.97/4.20

SEER*/SCOP** (energy performance class)

7.4(А++)/4.63(А++)

Air productive capacity

m3/h

520

Sound-pressure level

indoor unit/outdoor unit

dB(A)

24/28/34

51

Type of refrigerant coolant

R410А

Dimensions(width/height/depth)

indoor unit/outdoor unit

mm

770х283х201/710х550х318

Weight

indoor unit/outdoor unit

kg

8/28

Compressor type

rotor

Drainage

l/h

0.80

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-20/+24

Gas charge volume

kg

0.77

Liquid pipeline diameter

mm/inch

6.38/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

15

Distance between the bolts of the outdoor unit fastening

mm

470

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXN

Model

CH-S12FTXN

Capacity

Cold/Warm

kW

3.60(0.60-4.05)/4.12(0.60-5.25)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

Cold/Warm

kW

0.90 (0.22-1.45)/0.99(0.22-1.55)

Energy performance

EER (Cold)/C.O.P.(Warm)

kW/kW

4.00/4.20

SEER*/SCOP** (energy performance class)

7.1(А++)/4.7(А++)

Air productive capacity

m3/h

560

Sound-pressure level

indoor unit/outdoor unit

dB(A)

25/29/36

53

Type of refrigerant coolant

R410А

Dimensions(width/height/depth)

indoor unit/outdoor unit

mm

770х283х201/710х550х318

Weight

indoor unit/outdoor unit

kg

9/30

Compressor type

rotor

Drainage

l/h

1.40

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-20/+24

Gas charge volume

kg

1.00

Liquid pipeline diameter

mm/inch

6.38/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

15

Distance between the bolts of the outdoor unit fastening

mm

470

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S18FTXN

Model

CH-S18FTXN

Capacity

Cold/Warm

kW

5.30 (1.05-6.50)/5.70(1.00-7.00)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

Cold/Warm

kW

1.31 (0.36-2.50)/1.35(0.35-2.60)

Energy performance

EER (Cold)/C.O.P.(Warm)

kW/kW

4.05/4.22

SEER*/SCOP** (energy performance class)

7.1(А++)/4.6(А++)

Air productive capacity

m3/h

800

Sound-pressure level

indoor unit/outdoor unit

dB(A)

29/34/38

54

Type of refrigerant coolant

R410А

Dimensions(width/height/depth)

indoor unit/outdoor unit

mm

865х305х215/899х596х378

Weight

indoor unit/outdoor unit

kg

12/52

Compressor type

rotor

Drainage

l/h

1.80

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-20/+24

Gas charge volume

kg

1.10

Liquid pipeline diameter

mm/inch

6.38/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

Distance between the bolts of the outdoor unit fastening

mm

550

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S24FTXN

Model

CH-S24FTXN

Capacity

Cold/Warm

kW

6.45(1.50-7.00)/7.00(1.20-7.80)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

Cold/Warm

kW

1.85 (0.35-2.50)/1.98(0.35-2.70)

Energy performance

EER (Cold)/C.O.P.(Warm)

kW/kW

3.49/3.54

SEER*/SCOP** (energy performance class)

6.5(А++)/4.3(А+)

Air productive capacity

m3/h

1000

Sound-pressure level

indoor unit/outdoor unit

dB(A)

31/35/40

55

Type of refrigerant coolant

R410А

Dimensions(width/height/depth)

indoor unit/outdoor unit

mm

1008х319х221/955х700х396

Weight

indoor unit/outdoor unit

kg

15/55

Compressor type

rotor

Drainage

l/h

2.00

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-20/+24

Gas charge volume

kg

1.40

Liquid pipeline diameter

mm/inch

6.38/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

Distance between the bolts of the outdoor unit fastening

mm

560

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.


LAE ALLA:

Cooper & Hunter Support

-

Support 24H

Please fill out all required fields