Heatpump VIP INVERTER series

SAVE ENERGY

with Cooper&Hunter
innovation involves…

  • Сooling from -18°С to +54°С

  • Heating from -30°С to +24°С

EAC CE RoHS inverter-EUR

Vip-Inverter_big


DESCRIPTION:

  • Protects your home from freezing: function “+ eight degrees.” Air conditioner maintains temperature + 8 °C, do not freeze and consumes power minimum. This is especially useful for country houses and cottages without central heating;
  • A new inverter double stage compressor provides effective operation in the temperature range: cooling from -18°С to +54°С, heating from -30°С to +24°С, and increases EER for 40% during the cooling, and on 35% during the heating (COP);
  • Noiseless operation of the indoor unit 18 dB(A);
  • Wi-Fi module to control the air conditioner using the smartphone/tablet (ОS: Android, iOS);
  • Air flow distribution angle (to 180° horizontally and 130° vertically) allows achievement of maximum comfort and air balanced distribution in the room
Active carbon filter AIR1 Auto restart Auto swing louver Generation IV  I FEEL IONIZER LIGHT R410A Self diagnosis Self diagnosis error protection Warranty WI-FI X-fan 8 C 24hr Timer mode A+++ Super-silent Intelligent-defrost-function LED-display Multi-speed-fan Sleep Сooling Dehumidification Heating

MODELS:

CH-S09FTXHV-B

Model

CH-S09FTXHV-B

Capacity

cold/warm

kW

2.60(0.38-4.4)/3.00(0.38-5.1)

Electric power supply

~220V/50 Hz/1Ph

Rated input

cold/warm

kW

0.52(0.075-1.30)/0.55(0.07-1.4)

Energy performance

EER/C.O.P.

kW

5.0/5.45

SEER*/SCOP** (energy performance class)

8.5(А+++)/5.1(А+++)

Air productive capacity

m3/h

650/530/470/400/350/300/290

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(А)

37/34/32/28/24/21/18

45

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

860х305х170/899х596х378

Weight

indoor unit/outdoor unit

kg

11.5/44.5

Compressor type

rotor

Drainage

l/h

0.80

Operational temperature range cooling

°C

-18/+54

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.3

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

15

Distance between the bolts of the outdoor unit fastening

mm

550

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXHV-B

Model

CH-S12FTXHV-B

Capacity

cold/warm

kW

3.50(0.39-4.8)/3.70(0.4-5.7)

Electric power supply

~220V/50 Hz/1Ph

Rated input

cold/warm

kW

0.76(0.08-1.5)/0.75(0.08-1.6)

Energy performance

EER/C.O.P.

kW

4.6/4.93

SEER*/SCOP** (energy performance class)

8.5(А+++)/5.1(А+++)

Air productive capacity

m3/h

720/550/490/420/370/320/290

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(А)

40/38/34/32/28/24/20

50

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

860×305х170/899х596х378

Weight

indoor unit/outdoor unit

kg

11.5/44.5

Compressor type

rotor

Drainage

l/h

1.40

Operational temperature range cooling

°C

-18/+54

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.3

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

20

Distance between the bolts of the outdoor unit fastening

mm

550

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S18FTXHV-B

Model

CH-S18FTXHV-B

Capacity

cold/warm

kW

5.30(0.85-6.77)/5.30(0.75-7.32)

Electric power supply

~220V/50 Hz/1Ph

Rated input

cold/warm

kW

1.40(0.2-2.0)/1.35(0.2-2.4)

Energy performance

EER/C.O.P.

kW

3.8/3.93

SEER*/SCOP** (energy performance class)

6.1(А++)/4.6(А++)

Air productive capacity

m3/h

850/750/650/600/500/400/340

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(А)

46/42/40/36/32/27/22

56

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

960х320х205/965х700х396

Weight

indoor unit/outdoor unit

kg

14/51

Compressor type

rotor

Drainage

l/h

1.80

Operational temperature range cooling

°C

-18/+54

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.65

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

Distance between the bolts of the outdoor unit fastening

mm

560

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.