UNITHERM Series

inverter-EUR

DESCRIPTION:

Heat Pumps For Heating And Hot Water Supply

Functions and advantages

  • Heating of the room; Cooling of the room,
  • Water heating for hot water supply,
  • Cooling of the room and water heating,
  • Heating of the room and water heating,
  • Automatic climate control,
  • Emergency water heating mode,
  • Quick water heating,
  • Noiseless (night) mode,
  • Anti-frizzing mode,
  • Sanitary mode (heating of water in the boiler to 80°С),
  • Programming unit for 7 days,
  • Central control.

Outdoor unit

  • DC-inverter double-rotor,
  • compressor of a new generation,
  • Highly-performance structure,
  • of the heat exchange unit and ventilator,
  • High class of energy efficiency А: C.O.P 4,5,
  • Safe start and operation within the range from 95 W to 260 W,
  • Wide temperature range of effective operation: from -20°С when heating and up to +48°С when cooling,
  • Compressor starts with low inrush current (up to 5А),
  • Multi-level protection system,
  • Energy saving mode.

indoor unit

  • Gorgeous design and compact size (900х500х324 mm),
  • Plate type heat exchanger with the maximum energy efficiency ratio С.O.P,
  • Reliable and express pump,
  • Intellectual control system.

Boiler* (200l, 300l)

  • Is installed into the hot water supply system,
  • Boiler and heat exchanger are made of stainless steel,
  • Magnesium anod (effective scale protection),
  • Two temperature sensors,
  • Easy use and maintenance.

*Additional paid option

R410A


MODELS:

CH-HP8.0SINK

Model

CH-HP8.0SINK

Сapacity (for the warm floor)

cold/warm

kW

8.50/8.50

Rated input (for the warm floor)

cold/warm

kW

2.45/2.05

Energy performance (for the warm floor)

cold/warm

EER/COP

3.35/4.15

Electric power supply

~ 220-240V/50Hz/1Ph(~ 380-415V/50Hz/3Ph)

Capacity (for fan coil unit or radiator)

cold/warm

kW

6.20/7.50

Rated input (for fan coil unit or radiator)

cold/warm

kW

2.38/2.50

Energy performance (for fan coil unit or radiator)

cold/warm

EER/COP

2.61/3.00

Weight of refrigerant coolant

kg

2.1

Sound-pressure level

indoor unit/otdoor unit

dB(A)

31/55

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

500х900х324/980х790х360

Weight

indoor unit/outdoor unit

kg

53/78.5

Operational temperature range

°C

up to +7 for cooling/up to +55 for heating (up to +70 in the sanitary mode)

Operational temperature range

°C

-20/+48

Liquid pipeline diameter

mm/inch

9.53/3/8

Gas pipeline diameter

mm/inch

15.88/5/8

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

CH-HP10SINK

Model

CH-HP10SINK

Сapacity (for the warm floor)

cold/warm

kW

10.00/9.60

Rated input (for the warm floor)

cold/warm

kW

3.28/2.36

Energy performance (for the warm floor)

cold/warm

EER/COP

3.35/4.15

Electric power supply

~ 220-240V/50Hz/1Ph(~ 380-415V/50Hz/3Ph)

Capacity (for fan coil unit or radiator)

cold/warm

kW

7.50/8.50

Rated input (for fan coil unit or radiator)

cold/warm

kW

3.00/2.79

Energy performance (for fan coil unit or radiator)

cold/warm

EER/COP

2.50/3.05

Weight of refrigerant coolant

kg

2.1

Sound-pressure level

indoor unit/otdoor unit

dB(A)

31/55

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

500х900х324/980х790х360

Weight

indoor unit/outdoor unit

kg

53/78.5

Operational temperature range

°C

up to +7 for cooling/up to +55 for heating (up to +70 in the sanitary mode)

Operational temperature range

°C

-20/+48

Liquid pipeline diameter

mm/inch

9.53/3/8

Gas pipeline diameter

mm/inch

15.88/5/8

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

CH-HP12SINK(M)

Model

CH-HP12SINK(M)

Сapacity (for the warm floor)

cold/warm

kW

12.50(13.50)/12.50(13.50)

Rated input (for the warm floor)

cold/warm

kW

3.57(3.46)/2.80(2.75)

Energy performance (for the warm floor)

cold/warm

EER/COP

3.50(3.90)/4.45(4.55)

Electric power supply

~ 220-240V/50Hz/1Ph(~ 380-415V/50Hz/3Ph)

Capacity (for fan coil unit or radiator)

cold/warm

kW

9.50(9.50)/11.00(11.50)

Rated input (for fan coil unit or radiator)

cold/warm

kW

3.39(3.17)/3.14(3.38)

Energy performance (for fan coil unit or radiator)

cold/warm

EER/COP

2.80(3.00)/3.50(3.40)

Weight of refrigerant coolant

kg

3.2(3.40)

Sound-pressure level

indoor unit/otdoor unit

dB(A)

31/57

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

500х900х324/950х1345х412

Weight

indoor unit/outdoor unit

kg

53/106(107)

Operational temperature range

°C

up to +7 for cooling/up to +55 for heating (up to +70 in the sanitary mode)

Operational temperature range

°C

-20/+48

Liquid pipeline diameter

mm/inch

9.53/3/8

Gas pipeline diameter

mm/inch

15.88/5/8

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

CH-HP14SINK(M)

Model

CH-HP14SINK(M)

Сapacity (for the warm floor)

cold/warm

kW

13.50(14.50)13.50(14.20)

Rated input (for the warm floor)

cold/warm

kW

4.09(3.91)/3.06(3.23)

Energy performance (for the warm floor)

cold/warm

EER/COP

3.30(3.71)/4.40(4.40)

Electric power supply

~ 220-240V/50Hz/1Ph(~ 380-415V/50Hz/3Ph)

Capacity (for fan coil unit or radiator)

cold/warm

kW

10.00(10.50)/12.00(12.50)

Rated input (for fan coil unit or radiator)

cold/warm

kW

3.57(3.56)/3.36(3.62)

Energy performance (for fan coil unit or radiator)

cold/warm

EER/COP

2.80(2.95)/3.45(3.45)

Weight of refrigerant coolant

kg

3.2(3.4)

Sound-pressure level

indoor unit/otdoor unit

dB(A)

31/57

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

500х900х324/950х1345х412

Weight

indoor unit/outdoor unit

kg

53/106(107)

Operational temperature range

°C

up to +7 for cooling/up to +55 for heating (up to +70 in the sanitary mode)

Operational temperature range

°C

-20/ +48

Liquid pipeline diameter

mm/inch

9.53/3/8

Gas pipeline diameter

mm/inch

15.88/5/8

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

CH-HP16SINK(M)

Model

CH-HP16SINK(M)

Сapacity (for the warm floor)

cold/warm

kW

14.50(15.0)15.50(16.50)

Rated input (for the warm floor)

cold/warm

kW

4.53(4.11)/3.78(3.47)

Energy performance (for the warm floor)

cold/warm

EER/COP

3.20(3.65)/4.10(4.10)

Electric power supply

~ 220-240V/50Hz/1Ph(~ 380-415V/50Hz/3Ph)

Capacity (for fan coil unit or radiator)

cold/warm

kW

10.50(11.00)/14.00(14.00)

Rated input (for fan coil unit or radiator)

cold/warm

kW

3.96(3.73)/4.00(4.12)

Energy performance (for fan coil unit or radiator)

cold/warm

EER/COP

2.65(2.95)/3.50(3.40)

Weight of refrigerant coolant

kg

3.2(3.4)

Sound-pressure level

indoor unit/otdoor unit

dB(A)

31/59

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

500х900х324/950х1345х412

Weight

indoor unit/outdoor unit

kg

53/106(107)

Operational temperature range

°C

up to +7 for cooling/up to +55 for heating (up to +70 in the sanitary mode)

Operational temperature range

°C

-20/+48

Liquid pipeline diameter

mm/inch

9.53/3/8

Gas pipeline diameter

mm/inch

15.88/5/8

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30