NEW! Heatpump SUPREME series

ESPECIALLY DESIGNED FOR WORKING IN NORTH-EUROPEAN CLIMATE
CONDITIONS FOR USING THE HEAT-ENERGY AVAILABLE THERE

„CH SMART-ION Filter”- The new generation air filtering technology.
Model is available in three color variations:
Black, gold, silver

 

EAC CE RoHS inverter-EUR


DESCRIPTION:

supreme-set-small

  • The newest 2–stage inverter-compressor which will ensure operating in temperature range -30 C until +54 C,
  • Wi-Fi module for controlling the conditioner via smartphone/IPad (ОS: Android, iOS),
  • Extremely low noise – Just 18 dB, Case is fully plastic made and new heat-exchange technology without junctions,
  • Highest energy-efficiency class. The level of energy saving meets the type A+++ Class Energy Efficiency+ Generation V,
  • Stylish and compact design.
Active carbon filter AIR1 Auto restart Auto swing louver Generation IV  I FEEL IONIZER LIGHT  Self diagnosis Self diagnosis error protection Warranty WI-FI X-fan 8 C 24hr Timer mode A+++ Super-silent Intelligent-defrost-function LED-display Multi-speed-fan Sleep Сooling Dehumidification Heating

MODELS:

CH-S09FTXAM2S-BL/GD/SC

Model

CH-S09FTXAM2S-BL/GD/SC

Capacity

cold/warm

kW

2.7 (0.70-5.00)/3.5 (0.70-5.50)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.55 (0.08-1.80)/0.75 (0.13-2.40)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.90/4.66

SEER*/SCOP** (energy performance class)

8.5(А+++)/5.1(А+++)

Air productive capacity

m3/h

650/600/550/500/450/400/350

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

18/22/26/30/34/38/43/53

Type of refrigerant coolant

R32

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

996x301x225/899x596x378

Weight

indoor unit/outdoor unit

kg

13/44.5

Compressor type

rotor

Drainage

l/h

0.8

Operational temperature range cooling

°C

-15/+54

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.0

Liquid pipeline diameter

mm/inch

6.35/1/4″

Gas pipeline diameter

mm/inch

9.53/3/8″

Maximum pipeline level difference

m

10

Pipeline maximum length

m

15

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXAM2S-BL/GD/SC

Model

CH-S12FTXAM2S-BL/GD/SC

Capacity

cold/warm

kW

3.53 (0.85-5.00)/4.20 (0.88-7.20)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.84 (0.06-1.90)/0.95 (0.13-2.60)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.20/4.42

SEER*/SCOP** (energy performance class)

8.5(А+++)/5.1(А+++)

Air productive capacity

m3/h

650/600/550/500/450/400/350

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

20/24/28/32/34/36/41/46/54

Type of refrigerant coolant

R32

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

996x301x225/899x596x378

Weight

indoor unit/outdoor unit

kg

13/44.5

Compressor type

rotor

Drainage

l/h

1.4

Operational temperature range cooling

°C

-18/+54

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.0

Liquid pipeline diameter

mm/inch

6.35/1/4″

Gas pipeline diameter

mm/inch

9.53/3/8″

Maximum pipeline level difference

m

10

Pipeline maximum length

m

20

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S18FTXAM2S-BL/GD/SC

Model

CH-S18FTXAM2S-BL/GD/SC

Capacity

cold/warm

kW

5.30 (1.2-7.20)/5.57 (1.2-9.2)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.32 (0.35-2.50)/1.32 (0.35-3.30)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.01/4.21

SEER*/SCOP** (energy performance class)

6.6(A++)/4.4(A+)

Air productive capacity

m3/h

950/870/790/710/630/560/480

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

650/600/550/500/450/400/350

Type of refrigerant coolant

R32

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

1101x327x225/1000x790x427

Weight

indoor unit/outdoor unit

kg

16.5/64

Compressor type

rotor

Drainage

l/h

1.8

Operational temperature range cooling

°C

-15/+54

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.5

Liquid pipeline diameter

mm/inch

6.35/1/4″

Gas pipeline diameter

mm/inch

15.88/5/8″

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S24FTXAM2S-BL/GD/SC

Model

CH-S24FTXAM2S-BL/GD/SC

Capacity

cold/warm

kW

7.03 (2.00-9.00)/7.03 (2.00-9.50)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.85 (0.45-3.70)/1.75 (0.38-3.80)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

3.80/4.01

SEER*/SCOP** (energy performance class)

6.5(А++)/4.1(А+)

Air productive capacity

m3/h

650/600/550/500/450/400/350

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

32/35/38/41/44/47/50/56

Type of refrigerant coolant

R32

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

1101x327x225/1000x790x427

Weight

indoor unit/outdoor unit

kg

16.5/64

Compressor type

rotor

Drainage

l/h

2.0

Operational temperature range cooling

°C

-15/+54

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

2.0

Liquid pipeline diameter

mm/inch

6.35/1/4″

Gas pipeline diameter

mm/inch

15.88/5/8″

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.