Heatpump NORDIC EVO series

ENJOY FRESH AIR FOR BETTER HEALTH

The unique technology of CH 7-SKY means the seven air purification steps.

 

EAC CE RoHS inverter-EUR


DESCRIPTION:

  • Bigger structure for better performance and higher efficiency,
  • Elegant LED display, hidden when the unit is off,
  • Controlled by step-less regulation technology, the fan speed be adjust 1% to 100% between the highest and lowest speed,
  • Operating temperature range: cooling from +18°С to +48°C, heating from -23°С to +24°C.
WI-FIsmart ionActive carbon filterAIR1Intelligent-defrost-functionR410AAIR1Auto swing louverI FEELLIGHTSelf diagnosisSelf diagnosis error protectionWarrantyX-fan24hr Timer mode8 CIntelligent-defrost-functionLED-displaySleepDehumidificationAuto restartGeneration IVSuper-silent

MODELS:

CH-S09FTXN-E2wf

Model

CH-S09FTXN-E2wf

Capacity

cold/warm

kW

0.58 (0.075-1.43)/0.65 (0.135-1.55)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.81/0.78

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.32/4.51

SEER*/SCOP**

6.3 (A ++)/4.8 (A++)

Air productive capacity

m3/h

520/440/230/150

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

40/36/24/19

52

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

8721x274x195/830x540x325

Weight

indoor unit/outdoor unit

kg

9/29

Compressor type

rotor

Drainage

l/h

0.8

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-23/+24

Gas charge volume

kg

0.7

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

20

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXN-E2wf

Model

CH-S12FTXN-E2wf

Capacity

cold/warm

kW

03.40 (1.30-3.90)/3.60 (0.80-4.20)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.79 (0.09-1.56)/0.80 (0.14-1.65)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.32/4.51

SEER*/SCOP**

6.3 (A ++)/4.8 (A++)

Air productive capacity

m3/h

550/470/250/180

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

41/37/25/20

53

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

721x274x195/830x540x325

Weight

indoor unit/outdoor unit

kg

9/30

Compressor type

rotor

Drainage

l/h

1.4

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-23/+24

Gas charge volume

kg

0.9

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

20

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S24FTXN-E2wf

Model

CH-S24FTXN-E2wf

Capacity

cold/warm

kW

6.45 (1.40-7.00)/6.60 (1.50-7.90)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.50 (0.38-2.80)/1.425 (0.40-2.5)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.30/4.63

SEER*/SCOP**

6.3 (A ++)/4.8 (A++)

Air productive capacity

m3/h

1150/1050/950/850

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

48/45/42/28

60

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

1081x327x248/960x700x396

Weight

indoor unit/outdoor unit

kg

16.5/43.5

Compressor type

rotor

Drainage

l/h

2.0

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-23/+24

Gas charge volume

kg

1.5

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S18FTXN-E2wf

Model

CH-S18FTXN-E2wf

Capacity

cold/warm

kW

5.13 (1.00-6.70)/5.27 (1.10-6.80)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.19 (0.32-2.56)/1.138 (0.35-2.30)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.32/4.63

SEER*/SCOP**

6.3 (A ++)/4.8 (A++)

Air productive capacity

m3/h

850/720/610/520

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

46/42/39/28

56

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

972x302x224/960x700x396

Weight

indoor unit/outdoor unit

kg

14/43

Compressor type

rotor

Drainage

l/h

1.8

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-23/+24

Gas charge volume

kg

1.25

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.


DOWNLOAD:

Share:


Cooper & Hunter Support

-

Support 24H

Please fill out all required fields