Nordic Commercial FLOOR STANDING TYPE Series

EAC CE RoHS


DESCRIPTION:

  • Multi-rate fan,
  • “warm” start,
  • Four-sided air delivery,
  • Timer,
  • “Turbo” mode,
  • Display,
  • Self-diagnosis,
  • Self-cleaning mode,
  • Autorestart,
  • Clock-faced display,
  • Control panel lock,
  • Intellectual defrost,
  • Supplementary electric heating unit,
  • Night mode.
R410A

MODELS:

CHF60AD-M3NNA2A

  • Build-in electric heating element allows the air conditioner to be effective heater unit (3000 W)
  • The increased heating area – up to 200 m2 (600 m3)

 

Model

CHF60AD-M3NNA2A *

Capacity

cold/warm/E-heater

kW

16/18/3

Electric power supply

~ 380-415V/50Hz/3Ph

Rated input

cold/warm

kW

6.27.8

Energy performance

EER (cold)/C.O.P. (warm)

kW/kW

2.51/2.91

Air productive capacity

m3/h

2000

Sound-pressure level

indoor unit (min/ave/max)/outdoor unit

dB(A)

50/53/58

61

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

540х1750х380/950х1250х412

Weight

indoor unit/outdoor unit

kg

60/115

Operational temperature range

°C

-7/+43

Liquid pipeline diameter

inch

1/2’’

Gas pipeline diameter

inch

3/4’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

30

CHF48FH-M3NNB1B

Model

CHF48FH-M3NNB1B

Capacity

cold/warm/E-heater

kW

12.31/14.65/-

Electric power supply

~ 380-415V/50Hz/3Ph

Rated input

cold/warm

kW

4.725.05

Energy performance

EER (cold)/C.O.P. (warm)

kW/kW

2.4/2.58

Air productive capacity

m3/h

1800

Sound-pressure level

indoor unit (min/ave/max)/outdoor unit

dB(A)

46/48/50/52

59

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

580х1870х395/1032х1250х412

Weight

indoor unit/outdoor unit

kg

60/105

Operational temperature range

°C

-7/+43

Liquid pipeline diameter

inch

1/2’’

Gas pipeline diameter

inch

3/4’’

Maximum pipeline level difference

m

20

Pipeline maximum length

m

30