Nordic Commercial DUCT TYPE Series

EAC CE RoHS inverter-EUR


DESCRIPTION:

  • Compact size,
  • Low noise level,
  • Long-life washable filter,
  • Self-diagnosis of the main units and modes,
  • Defense from the incorrect connection to the power supply,
  • Length of the pipeline is up to 50 m.
Auto restartAuto restart R410A Self diagnosis Self diagnosis error protection24hr Timer mode Super-silent Intelligent-defrost-function Multi-speed-fan Sleep Сooling Dehumidification Heating


MODELS:

CH-ID09NK4/CH-IU09NK4

Model

CH-ID09NK4/CH-IU09NK4

Capacity

cold/warm

kW

2.7/2.9

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.84/0.8

Input rate

cold

А

3.9

Input rate

warm

3.7

Energy performance

cold/warm

EER/COP

3.21/3.61

Air capability

indoor unit

m3/h

650

Nominal pressure

indoor unit

Ра

25

Pressure level

indoor unit

Ра

0-30

Sound-pressure level

indoor unit/outdoor unit

dB(A)

36/34/28/26

52

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

1.2

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

925x665x250/

848x320x540

Weight

indoor unit/outdoor unit

kg

27/34

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

9.53/ 3/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Quantity of interblock strands (for control)

2*0.75 – up to 20 m long

Main power supply arrea

outdoor.

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.5 mm)

Factory Freon fill (per the number of running meters)

m.

5

Volumeoffreon.

grаmm/m.p.

30

SEER/SCOP

5.6/3.8

CH-ID12NK4/CH-IU12NK4

Model

CH-ID12NK4/CH-IU12NK4

Capacity

cold/warm

kW

3.50/3.80

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.17/1.05

Input rate

cold

А

5.40

Input rate

warm

4.90

Energy performance

cold/warm

EER/COP

3.0/3.61

Air capability

indoor unit

m3/h

750

Nominal pressure

indoor unit

Ра

25

Pressure level

indoor unit

Ра

0-35

Sound-pressure level

indoor unit/outdoor unit

dB(A)

37/36/34/28

52

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

1.2

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1037х721х266/

848х320х540

Weight

indoor unit/outdoor unit

kg

33/34

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

9.53/ 3/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Quantity of interblock strands (for control)

2*0.75 – up to 20 m long

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.5 mm)

Factory Freon fill (per the number of running meters)

m.

5

Volumeoffreon.

grаmm/m.p.

30

SEER/SCOP

5.6/4.0

CH-ID18NK4/CH-IU18NK4

Model

CH-ID18NK4/CH-IU18NK4

Capacity

cold/warm

kW

5.0/5.6

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.55/1.55

Input rate

cold

А

7.50

Input rate

warm

7.40

Energy performance

cold/warm

EER/COP

3.23/3.61

Air capability

indoor unit

m3/h

1000

Nominal pressure

indoor unit

Ра

25

Pressure level

indoor unit

Ра

0-35

Sound-pressure level

indoor unit/outdoor unit

dB(A)

40/39/36/28

56

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

1.4

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1037х721х266/

955х396х700

Weight

indoor unit/outdoor unit

kg

33/47

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

6.35/ 1/4’’

Gas pipeline diameter

mm/inch

12.70/ 1/2’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

20

Quantity of interblock strands (for control)

2*0.75 – up to 20 m long

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

3(?2.5 mm)

Factory Freon fill (per the number of running meters)

m.

5

Volumeoffreon.

grаmm/m.p.

30

SEER/SCOP

5.6/3.8

CH-ID24NK4/CH-IU24NK4

Model

CH-ID24NK4/CH-IU24NK4

Capacity

cold/warm

kW

7.00/8.00

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

2.18/2.21

Input rate

cold

А

10.10

Input rate

warm

10.20

Energy performance

cold/warm

EER/COP

3.21/3.62

Air capability

indoor unit

m3/h

1400

Nominal pressure

indoor unit

Ра

25

Pressure level

indoor unit

Ра

0-75

Sound-pressure level

indoor unit/outdoor unit

dB(A)

47/46/44/40

57

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

2.2

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1279х558х268/

980х427х790

Weight

indoor unit/outdoor unit

kg

34/67

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

Quantity of interblock strands (for control)

2*0.75 – up to 20 m long

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

3(?2.5 mm)

Factory Freon fill (per the number of running meters)

m.

5

Volumeoffreon.

grаmm/m.p.

60

SEER/SCOP

6.1/4.0

CH-ID30NK4/CH-IU30NK4

Model

CH-ID30NK4/CH-IU30NK4

Capacity

cold/warm

kW

8.3/9.2

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

2.67/2.57

Input rate

cold

А

12.4

Input rate

warm

12.0

Energy performance

cold/warm

EER/COP

3.11/3.58

Air capability

indoor unit

m3/h

1400

Nominal pressure

indoor unit

Ра

37

Pressure level

indoor unit

Ра

0-75

Sound-pressure level

indoor unit/outdoor unit

dB(A)

47/46/44/40

58

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

2.4

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1279х558х268/

980х427х790

Weight

indoor unit/outdoor unit

kg

34/71

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

Quantity of interblock strands (for control)

2*1.0 – if longer than 20 m

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

3(?2.5 mm)

Factory Freon fill (per the number of running meters)

m.

5

Volumeoffreon.

grаmm/m.p.

60

SEER/SCOP

6.1/4.0

CH-ID36NK4/ CH-IU36NM4

Model

CH-ID36NK4/ CH-IU36NM4

Capacity

cold/warm

kW

10.00/12.00

Electric power supply

~380-415V/50РHz/3Ph

Rated input

cold/warm

kW

3.12/3.32

Input rate

cold

А

5.40

Input rate

warm

А

5.80

Energy performance

cold/warm

EER/COP

3.21/3.61

Air capability

indoor unit

m3/h

2100

Nominal pressure

indoor unit

Ра

37

Pressure level

indoor unit

Ра

0-100

Sound-pressure level

indoor unit/outdoor unit

dB(A)

53/52/48/44

63

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

3.5

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1226х775х290/

1107х440х1100

Weight

indoor unit/outdoor unit

kg

46/98

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

15

Pipeline maximum length

m

30

Quantity of interblock strands (for control)

2*1.0 – if longer than 20 m

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

5(?1.5 mm)

Factory Freon fill
(per the number of running meters)

m.

5

Volumeoffreon.

grаmm/m.p.

60

SEER/SCOP

5.1/4.0

CH-ID42NK4/ CH-IU42NM4

Model

CH-ID42NK4/ CH-IU42NM4

Capacity

cold/warm

kW

11.50/13.50

Electric power supply

~380-415V/50РHz/3Ph

Rated input

cold/warm

kW

4.0/3.9

Input rate

cold

А

6.90

Input rate

warm

А

6.70

Energy performance

cold/warm

EER/COP

2.88/3.46

Air capability

indoor unit

m3/h

2100

Nominal pressure

indoor unit

Ра

37

Pressure level

indoor unit

Ра

0-100

Sound-pressure level

indoor unit/outdoor unit

dB(A)

53/52/48/44

61

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

3.7

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1226х775х290/

958х412х1349

Weight

indoor unit/outdoor unit

kg

46/108

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Quantity of interblock strands (for control)

2*1.0 – if longer than 20 m

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

5(?2.5 mm)

Factory Freon fill
(per the number of running meters)

m.

5

Volumeoffreon.

grаmm/m.p.

60

SEER/SCOP

5.6/4.0

CH-ID48NK4/ CH-IU48NM4

Model

CH-ID48NK4/ CH-IU48NM4

Capacity

cold/warm

kW

14.00/15.50

Electric power supply

~380-415V/50РHz/3Ph

Rated input

cold/warm

kW

5.1/4.5

Input rate

cold

А

8.80

Input rate

warm

А

7.80

Energy performance

cold/warm

EER/COP

2.75/3.44

Air capability

indoor unit

m3/h

2400

Nominal pressure

indoor unit

Ра

50

Pressure level

indoor unit

Ра

0-125

Sound-pressure level

indoor unit/outdoor unit

dB(A)

55/53/49/45

59

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

4.0

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1340х750х350/

958х412х1349

Weight

indoor unit/outdoor unit

kg

56/114

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

15.88/ 5/8’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Quantity of interblock strands (for control)

2*1.0 – if longer than 20 m

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

5(?2.5 mm)

Factory Freon fill
(per the number of running meters)

m.

7.5

Volumeoffreon.

grаmm/m.p.

60

SEER/SCOP

5.6/3.8

CH-ID60NK4/ CH-IU60NM4

Model

CH-ID60NK4/ CH-IU60NM4

Capacity

cold/warm

kW

16.00/16.50

Electric power supply

~380-415V/50РHz/3Ph

Rated input

cold/warm

kW

5.6/4.57

Input rate

cold

А

9.7

Input rate

warm

А

7.9

Energy performance

cold/warm

EER/COP

2.86/3.61

Air capability

indoor unit

m3/h

3000

Nominal pressure

indoor unit

Ра

50

Pressure level

indoor unit

Ра

0-150

Sound-pressure level

indoor unit/outdoor unit

dB(A)

57/56/54/49

63

Type of refrigerant coolant

R410A

Refrigerant coolant

kg

5.0

Dimension (width/height/depth)

indoor unit

outdoor unit

mm

1340/750/350

1085/427/1365

Weight

indoor unit/outdoor unit

kg

57/126

Operational temperature range

cold

°C

-15/+48

Operational temperature range

warm

°C

-20/+24

Liquid pipeline diameter

mm/inch

9.53/ 3/8’’

Gas pipeline diameter

mm/inch

19.05/ 3/4’’

Maximum pipeline level difference

m

30

Pipeline maximum length

m

50

Quantity of interblock strands (for control)

2*1.0 – if longer than 20 m

Main power supply arrea

outdoor

Quantity of the strands
(powersupply outdoor/indoor)

3(?1.0 mm)/

Quantity of the strands
(powersupply outdoor/indoor)

5(?2.5 mm)

Factory Freon fill
(per the number of running meters)

m.

7.5

Volumeoffreon.

grаmm/m.p.

60

SEER/SCOP

5.6/3.8


DOWNLOAD: