Heatpump CONSOL INVERTER series

IDEAL FOR OPERATION AS A HEAT PUMP

Enjoy innovation in every season with precise, quietly efficient INVERTER CONSOLE that keeps your life simply perfect.

 

EAC CE RoHS inverter-EUR


DESCRIPTION:

  • Wide temperature range: cooling from -15°С to +43°C, heating from -25°С to +24°C,
  • Slim-format (215 mm),
  • Wide-angled louvre-boards, control of air supply from the lower  and upper parts of the unit,
  • Automatic frost-up protection system Intelligent Preheating,
    Defrosting “over time” – in average 10 minutes of defrosting for 50 minutes of compressor operation.
Active carbon filter AIR1 Auto restart Auto swing louver IONIZER R410A Self diagnosis Self diagnosis error protection 24hr Timer mode  Intelligent-defrost-function LED-display Sleep Сooling Heating

MODELS:

CH-S09FVX

Model

CH-S09FVX

Capacity

cold/warm

kW

2.60 (0.45-3.20)/3.30 (0.45-3.75)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.66 (0.20-1.55)/0.81 (0.20-1.35)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

3.93/4.10

SEER*/SCOP**

6.5 (А++)/4.6 (А++)

Air productive capacity

m3/h

500

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

22/24/26/29/32/34/37

50

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

700х600х215/776х540х320

Weight

indoor unit/outdoor unit

kg

15/32

Compressor type

rotor

Drainage

l/h

0.8

Operational temperature range cooling

°C

-15/+43

Operational temperature range heating

°C

-25/+24

Weight of refrigerant coolant

kg

0.9

Liquid pipeline diameter

mm/inch

6.38/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

15

Distance between the bolts of the outdoor unit fastening

mm

510

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FVX

Model

CH-S12FVX

Capacity

cold/warm

kW

3.52 (0.60-3.95)/4.00 (0.60-4.70)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.98 (0.22-1.70)/1.00 (0.22-1.50)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

3.6/4

SEER*/SCOP**

6.3 (А++)/4.6 (А++)

Air productive capacity

m3/h

600

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

24/26/28/30/32/35/38

51

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

700х600х215/848х540х320

Weight

indoor unit/outdoor unit

kg

15/34

Compressor type

rotor

Drainage

l/h

1.8

Operational temperature range cooling

°C

-15/+43

Operational temperature range heating

°C

-25/+24

Weight of refrigerant coolant

kg

1.15

Liquid pipeline diameter

mm/inch

6.38/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

15

Distance between the bolts of the outdoor unit fastening

mm

540

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S18FVX

Model

CH-S18FVX

Capacity

cold/warm

kW

5.27 (0.90-5.60)/5.50 (0.90-6.60)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.42 (0.35-2.50)/1.53 (0.35-2.50)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

3.46/3.87

SEER*/SCOP**

5.8 (А+)/4.2 (А+)

Air productive capacity

m3/h

650

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

28/30/32/34/36/38/40

53

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

700х600х215/963х700х396

Weight

indoor unit/outdoor unit

kg

15/45

Compressor type

rotor

Drainage

l/h

2

Operational temperature range cooling

°C

-15/+43

Operational temperature range heating

°C

-25/+24

Weight of refrigerant coolant

kg

1.3

Liquid pipeline diameter

mm/inch

6.38/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

Distance between the bolts of the outdoor unit fastening

mm

560

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.


DOWNLOAD:

Share:


Cooper & Hunter Support

-

Support 24H

Please fill out all required fields