Heatpump ICY-II series

WI-FI AIR CONDITIONER CONTROL

 

The best solution to make your A/C smarter than ever.
For Android

 

EAC CE RoHS inverter-EUR


DESCRIPTION:

  • A new inverter double stage compressor provides effective operation in the temperature range:
    cooling from -15°С to +48°C, heating from -30°С to +24°C
  • Noiseless operation of the indoor unit 20 dB(A);
  • Wi-Fi modular to control the air conditioner using the smartphone/tablet (ОS: Android)

WI-FI – OPTIONAL

 

R410A Active carbon filter AIR1 Auto restart Auto swing louver Generation IV Inverter technology I FEEL IONIZER LIGHT Self diagnosis Self diagnosis error protection Warranty X-fan 8 C 24hr Timer mode A+++ Super-silent Intelligent-defrost-function LED-display Multi-speed-fan Sleep Сooling Dehumidification Heating

MODELS:

CH-S09FTXTB2S-W

Model

CH-S09FTXTB2S-W

Capacity

cold/warm

kW

2.60(0.76-4.81)/3.00(0.82-5.50)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.60(0.24-1.87)/0.65(0.21-2.00)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.33/4.62

SEER*/SCOP** (energy performance class)

8.5(А+++)/5.1(А+++)

Air productive capacity

m3/h

650/600/550/500/450/400/350

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

20/24/28/32/34/36/43/54

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

866х292х209/899х596х378

Weight

indoor unit/outdoor unit

kg

11/41

Compressor type

rotor

Drainage

l/h

0.8

Operational temperature range cooling

°C

-15/+48

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.20

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

9.38/3/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

15

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXTB2S-W

Model

CH-S12FTXTB2S-W

Capacity

cold/warm

kW

3.50 (1.11-4.0)/3.65 (2.0-5.3)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.89 (0.23-1.30)/0.90 (0.24-1.90)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

3.93/4.06

SEER*/SCOP** (energy performance class)

7.8(А++)/4.6(А++)

Air productive capacity

m3/h

740/670/610/530/460/410/380

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

22/24/28/32/34/36/45/55

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

866х292х209/940x372x286

Weight

indoor unit/outdoor unit

kg

11/43,5

Compressor type

rotor

Drainage

l/h

1.4

Operational temperature range cooling

°C

-15/+48

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.30

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

20

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S18FTXTB2S-W

Model

CH-S18FTXTB2S-W

Capacity

cold/warm

kW

5.27 (1.00-6.30)/5.45 (1.00-6.80)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

1.51 (0.40-2.45)/1.46 (0.45-2.50)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

3.5/3.72

SEER*/SCOP** (energy performance class)

6.5(А++)/4.0(А+)

Air productive capacity

m3/h

950/870/790/710/630/560/480

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

34/38/40/42/44/46/56

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

1018х319х230/955х700х396

Weight

indoor unit/outdoor unit

kg

14/51

Compressor type

rotor

Drainage

l/h

1.8

Operational temperature range cooling

°C

-15/+48

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

1.65

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S24FTXTB2S-W

Model

CH-S24FTXTB2S-W

Capacity

cold/warm

kW

7.00(1.90-9.00)/7.30 (1.90-9.00)

Electric power supply

~ 220-240V/50Hz/1Ph

Rated input

cold/warm

kW

2.00 (0.40-3.70)/1.96 (0.45-3.70)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

3.5/3.72

SEER*/SCOP** (energy performance class)

6.2 (++)/4.0 (+)

Air productive capacity

m3/h

1200/1130/1060/990/920/850/780

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

32/37/42/44/46/50/51/58

Type of refrigerant coolant

R410А

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

1178х326х264/980х790х427

Weight

indoor unit/outdoor unit

kg

17/65

Compressor type

rotor

Drainage

l/h

2.5

Operational temperature range cooling

°C

-15/+48

Operational temperature range heating

°C

-30/+24

Gas charge volume

kg

2.00

Liquid pipeline diameter

mm/inch

6.35/1/4’’

Gas pipeline diameter

mm/inch

15.88/5/8’’

Maximum pipeline level difference

m

10

Pipeline maximum length

m

25

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.