Heatpump ARCTIC DESIGN series

BEAUTIFUL NEW SLIM

AND COMPACT DESIGN

available in three colors:

white, champagne, metallic

 

EAC CE RoHS inverter-EUR


DESCRIPTION:

  • Temperature range of effective operation in the temperature range: cooling from +18°С to +48°C, heating from -25°С to +24°C
  • Slim-format 15,9 cm;
  • Defends your home from freezing: function “+8 degrees”;
  • White (FTXS-W), Champagne (FTXS-B), Metallic (FTXS-M).

Active carbon filter AIR1 Auto restart Auto swing louver Generation IV  I FEEL IONIZER LIGHT R410A Self diagnosis Self diagnosis error protection Warranty X-fan 8 C 24hr Timer mode A+++ Super-silent Intelligent-defrost-function LED-display Multi-speed-fan Sleep Сooling Dehumidification Heating

MODELS:

CH-S09FTXS-B

Model

CH-S09FTXS-B

Capacity

cold/warm

kW

2.79(0.76-3.38)/2.9(0.68-3.97)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.57(0.2-1.20)/0.58(0.16-1.25)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.85/4.95

SEER*/SCOP** (energy efficiency ratio)

8.6(А+++)/4.9(А++)

Air productive capacity

m3/h

1400/1200/1100/1000/900/800/700

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

21/25/27/29/32/34/38

50

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

896х320х159/776х540х320

Weight

indoor unit/outdoor unit

kg

11.5/29

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-25/+24

Liquid pipeline diameter

mm/inch

6/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Distance between the bolts of the outdoor unit fastening

mm

510

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S09FTXS-W

Model

CH-S09FTXS-W

Capacity

cold/warm

kW

2.79(0.76-3.38)/2.9(0.68-3.97)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.57(0.2-1.20)/0.58(0.16-1.25)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.85/4.95

SEER*/SCOP** (energy efficiency ratio)

8.6(А+++)/4.9(А++)

Air productive capacity

m3/h

1400/1200/1100/1000/900/800/700

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

21/25/27/29/32/34/38

50

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

896х320х159/776х540х320

Weight

indoor unit/outdoor unit

kg

11.5/29

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-25/+24

Liquid pipeline diameter

mm/inch

6/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Distance between the bolts of the outdoor unit fastening

mm

510

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S09FTXS-M

Model

CH-S09FTXS-M

Capacity

cold/warm

kW

2.79(0.76-3.38)/2.9(0.68-3.97)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.57(0.2-1.20)/0.58(0.16-1.25)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.85/4.95

SEER*/SCOP** (energy efficiency ratio)

8.6(А+++)/4.9(А++)

Air productive capacity

m3/h

1400/1200/1100/1000/900/800/700

Sound-pressure level

indoor unit/(max-min) outdoor unit

dB(A)

21/25/27/29/32/34/38

50

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

896х320х159/776х540х320

Weight

indoor unit/outdoor unit

kg

11.5/29

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-25/+24

Liquid pipeline diameter

mm/inch

6/1/4’’

Gas pipeline diameter

mm/inch

9.53/3/8’’

Distance between the bolts of the outdoor unit fastening

mm

510

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXS-B

Model

CH-S12FTXS-B

Capacity

cold/warm

kW

3.53(0.82-3.97)/3.97(0.74-4.56)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.77(0.36-1.30)/0.84(0.34-1.36)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.61/4.71

SEER*/SCOP** (energy efficient rating)

kW/kW

8.6(А+++)/4.9(А++)

Air productive capacity

m3/h

1400/1250/1150/1050/950/850/700

Noise level

indoor unit/outdoor unit

dB(A)

23/25/28/31/34/36/39

52

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

896x320x159/848x540x320

Weight

indoor unit/outdoor unit

kg

11.5/38

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-25/+24

Liquid pipeline diameter

mm/inch

6/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Distance between the bolts of the outdoor unit fastening

mm

540

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXS-W

Model

CH-S12FTXS-W

Capacity

cold/warm

kW

3.53(0.82-3.97)/3.97(0.74-4.56)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.77(0.36-1.30)/0.84(0.34-1.36)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.61/4.71

SEER*/SCOP** (energy efficient rating)

kW/kW

8.6(А+++)/4.9(А++)

Air productive capacity

m3/h

1400/1250/1150/1050/950/850/700

Noise level

indoor unit/outdoor unit

dB(A)

23/25/28/31/34/36/39

52

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

896x320x159/848x540x320

Weight

indoor unit/outdoor unit

kg

11.5/38

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-25/+24

Liquid pipeline diameter

mm/inch

6/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Distance between the bolts of the outdoor unit fastening

mm

540

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.

CH-S12FTXS-M

Model

CH-S12FTXS-M

Capacity

cold/warm

kW

3.53(0.82-3.97)/3.97(0.74-4.56)

Electric power supply

~220-240V/50Hz/1Ph

Rated input

cold/warm

kW

0.77(0.36-1.30)/0.84(0.34-1.36)

Energy performance

EER (Cold)/C.O.P. (Warm)

kW/kW

4.61/4.71

SEER*/SCOP** (energy efficient rating)

kW/kW

8.6(А+++)/4.9(А++)

Air productive capacity

m3/h

1400/1250/1150/1050/950/850/700

Noise level

indoor unit/outdoor unit

dB(A)

23/25/28/31/34/36/39

52

Type of refrigerant coolant

R410A

Dimensions (width/height/depth)

indoor unit/outdoor unit

mm

896x320x159/848x540x320

Weight

indoor unit/outdoor unit

kg

11.5/38

Operational temperature range cooling

°C

+18/+48

Operational temperature range heating

°C

-25/+24

Liquid pipeline diameter

mm/inch

6/1/4’’

Gas pipeline diameter

mm/inch

12.7/1/2’’

Distance between the bolts of the outdoor unit fastening

mm

540

 

* SEER – Seasonal Energy Efficient Ratingin the cooling mode. ** SCOP – seasonal system capacity ratio in the heating mode.